Australia, New Zealand Adopt IEC’s Hydrocarbon Charge Limit for Commercial Cabinets

2020-7-31

Standards Australia has adopted new limits on the amount of A3 (flammable) and A2L (low flammable) that is allowed to be used in commercial refrigeration appliances and ice makers in Australia and New Zealand.
The new standard (AS/NZS 60335.2.89:2020) is an “identical adoption” of IEC 60335-2-89, edition 3.0., published by the International Electrotechnical Commission June 2019, according Standard Australia’s website. The new Australia/New Zealand standard supersedes an earlier version adopted by the countries in 2010.

In IEC 60335-2-89, edition 3.0., IEC raised the charge limit for A3 (flammable) refrigerants in self-contained cases to 13 times the lower flammability limit (LFL) of the refrigerant; for propane (R290) it increases to 500 g from 150g. The IEC standard also increases the charge limit for A2 and A2L (low flammable) refrigerants to 1,200 g from 150 g.
Other countries around the world are also engaged in adopting IEC 60335-2-89, or modifications of it. In Japan, the Japan Refrigeration and Air Conditioning Industry Association (JRAIA) is working on the Japanese Industrial Standard (JIS) version of the IEC standard.
In June, UL (Underwriters Laboratories), the Northbrook, Illinois (U.S.)-based safety-certification company that publishes appliance standards for the U.S., released a proposed second edition of the UL 60335-2-89 standard for review, including updated charge limits for hydrocarbon and A2L refrigerants. The proposed UL standard, which incorporates CSA (Canadian Standards Association) 60335-2-89, calls for raising the A3 charge limit in commercial appliances to 13 times the LFL, but only for open appliances (without doors); it proposes raising the charge limit for closed appliances with doors and/or drawers to eight times the LFL of the flammable refrigerant (300g for R290).

Source: HYDROCARBONS21  https://wedocs.unep.org/bitstream/handle/20.500.11822/29244/8052HS_Codes_Brief.pdf?sequence=1&isAllowed=y

【抄訳】

オーストラリアとニュージーランド、IECによる業務用機器への炭化水素冷媒充塡量制限を採用

オーストラリア規格協会は、オーストラリアとニュージーランド国内において業務用冷凍機器及び製氷機への使用が許可されているA3(可燃性)及びA2L(微燃性)冷媒の新しい使用制限量を採用した。同協会ウェブサイトによると、新規格AS/NZS 60335.2.89:2020は、2019年6月にIECが発行したIEC 60335-2-89, edition 3.0.と同じ内容であり、両国が2010年に採用した前の版に置き換わるものである。
IEC 60335-2-89, edition 3.0.でIECは内蔵型機器に使用するA3(可燃性)冷媒の充塡量上限を、燃焼下限界(LFL)の13倍に引き上げた。プロパン(R290)の場合、150gから500gに増加する。IEC規格では、A2及びA2L冷媒についても充塡量上限を150gから1200gに増やした。
その他の国々でもIEC 60335-2-89, edition 3.0.又はその修正版の採用に取り組んでいる。日本においては、日本冷凍空調工業会(JRAIA)がIEC規格に倣った日本産業規格(JIS)を作成中である。